| APPLICATION |
New
San Andreas Water Injection Wells completed with Fiberglass
Casing |
| LOCATION |
Bennet
Ranch near Denver City, Texas |
| PRODUCT |
5
1/2" 2000 psi Casing, Threaded and Coupled |
| QUANTITY |
20
Wells completed since 1987
500 ft. to 1500 ft. of Fiberglass Casing used in the pay
area of each well |
SERVICE
CONDITIONS |
Total
depth 5200 ft. average, cemented in place with DV tool. Jet perforated, 2 to 4 shots per ft., hollow
carrier 10 to 13 gram select fire charges, Water
Injection Pressure 1400 psi. Water contains
polysulfide and iron sulfide, gradient 0.43. Reservoir
Pressure 2600 psi. Bottom Hole Injection Pressure 3550
psi, Bottom Hole Temp. 55 deg. F to 105 deg. F. cup type
packers set in some of the fiberglass. Certain wells
were installed with CRA joint above fiberglass for packer
setting. Steel ran above CRA or fiberglass. |
|
| APPLICATION |
Fiberglass
Tubing successfully repairs corroded 4 1/2" steel
casing |
| LOCATION |
Near
Eagle Pass, Texas |
| PRODUCT |
2
7/8" 2500 psi Tubing, Threaded and Coupled with special
O.D. Turned Down Collars |
| QUANTITY |
42
Wells completed in 1991, 36 Wells completed in 1992 |
SERVICE
CONDITIONS |
Approximately
1300 to 1700 ft. ran top to bottom in each well. Water
Injection 1000 psi, Injection Temp. 85 deg. F, Bottom Hole
Temp. 100 deg. F. The pipe is sandblasted and cemented
in place. Inflatable packers used in first 42 wells,
used two joints of steel on the bottom, the steel was
perforated. The 36 wells completed in 1992 were
installed using a polished bore receptacle with a latch
instead of an inflatable packer. A special cement shoe
was used on these 32 wells and the liner was stopped above
the original perforations. This saved the cost of two
joints of steel tubing, perforating and acidizing. |
|
| APPLICATION |
Fiberglass
Casing and Liners in service up to 20 years |
| LOCATION |
Denver
City, Texas |
| PRODUCT |
3
1/2" & 4 1/2" 2000 psi Tubing, Threaded and
Coupled (used for liner repair of corroded steel casing)
5 1/2" 2000 psi Casing, Threaded and Coupled (used in
new wells at the bottom of a steel string) |
| QUANTITY |
350
Injection Wells completed since 1971 at the Denver Unit
The fiberglass is ran through the corrosive pay area |
SERVICE
CONDITIONS |
Total
well depth 5200 ft., 500 ft. to 1500 ft. of fiberglass
cemented in place and perforated. Co2 and Water Wag
System began in 1984. Co2 Surface Injection 1800 psi,
Water Injection Pressure 1400 psi. Bottom Hole Temp.
55 deg. F to 105 deg. F. |
|
| APPLICATION |
High
Temperature Observation Well Casing |
| LOCATION |
Dubai
- October 1992 |
| PRODUCT |
5
1/2" 2000 psi Casing, Threaded and Coupled |
| QUANTITY |
416
ft. |
SERVICE
CONDITIONS |
Observation
Well Offshore
Total depth 9,305 ft.
Fiberglass Casing from 9,134 to 8,718 ft.
BH temperature 235 deg. F.
Cemented to surface. Wireline Tools |
|
| APPLICATION |
Japan
- September 1993 |
| PRODUCT |
7"
2000 psi Casing, Threaded and Coupled ACT |
SERVICE
CONDITIONS |
Oil
and Gas Production total depth 6,090 ft.
13 3/8" Steel Surface Casing 1,410 ft.
Fiberglass Casing ran from 1,410 ft. to 6,090ft.
41 degree deviation cemented from 4,055 ft. to surface
Perforated 7" fiberglass Casing with wire screen ran
from 4,055 to 6,090 ft. |
|
| APPLICATION |
Special
sized Carbon Fiber Coupling's increase liner size while
maintaining performance |
| LOCATION |
Oosaka,
Japan |
| PRODUCT |
5
1/2" 1500 spi Casing O.D. 5.80" Carbon Fiber
Coupling - 1,410 ft.
7" 1500 psi Casing combination tapered string cemented
in place - 1,260 ft. |
SERVICE
CONDITIONS |
Installed
in September 1993 |